Check Out Our Work in Cumming GA
Chen Plumbing provides air conditioning, heating, water heater and plumbing services to the residents of Cumming, GA and the surrounding areas since 1998!
Read our reviews and find out why your neighbors consider us to be their nearby heating and air company and local plumber in Cumming, GA.
Recent Jobs and Reviews in Cumming, GA
Cumming, GA at a glance
Chen Plumbing has completed 3 jobs in Cumming, GA between December 2025 and February 2026.
The most recent job was on February 3, 2026.
Chen Plumbing has completed 98 jobs in Cumming, GA in the last 12 months. The first job there was in July 2023.
Job Locations and Reviews
For this customer, they are claiming that they hear a sound from the water heater. It’s making a clicking noise however, when I was there couldn’t find the source of the clicking noise. We hear a clicking noise at all however, the water pressure is at 80 psi the pressure gauge that I have is off by 20 pounds. In addition to that pressure reducing valve needs to be replaced. The customer has a recirculation pump on their water heater that also needs to be replaced due to the fact that it is no longer working and functioning properly in addition to that the water heater at the bottom near the Burner assembly on the inside has a lot of rust and water buildup around the tank however, it is not leaking on the outside of the tank. It is definitely leaking somewhere internally. Recommend you get everything replaced as soon as possible.
Came out for a water heater the 5em Lot light was not staying lit. Water heater was 8-9 years. Received approval to replace the tank. Installed new Rheem 50 gallon gas after heater. Installed new expansion tank set to 75 psi. Tested to ensure proper function and a leak free install. No further issue at this time.
Call for toilet and tub backup. Arrived and met with Kristian. He states that the toilet and tub have been backed up, and sewage has leaked through garage ceiling. Sewage also came from under toilet on to the bathroom floor. While inspecting I ran water for approximately ten minutes (218-230pm) in the bathroom and was unable to replicate blockage. Blockage seems to have been on line serving upstairs bathroom and kitchen only, and downstairs bathroom has no signs of backup or leaks. Clean out outside shows no signs of overflowing, but is missing a cap. I believe this was a local soft tissue or grease blockage, and will provide an estimate to camera the sewer line. When inspecting sewer system I also discovered the pressure regulating valve has been dripping from corrosion on the incoming side. Pressure reads at 40psi at 255pm. Replaced dripping pressure regulating valve. Installed new thermal expansion tank and mounting bracket. Pressurized system and checked for leaks. Restoratio
